• Home
  • Risk audit
  • Pricing
  • Contact
  1. Home
  2. Risk audit
  3. Fire

Fire Risk Assessment & Prevention for Businesses

Fire risk is the probability that an uncontrolled fire will start and spread within a company's premises, endangering people, physical assets, and business operations.

It is one of the major risks to consider in any occupational risk assessment, because of its potential impact: loss of life, property destruction, business interruption, legal liability, and more.

Objectives of the fire risk assessment

The fire risk assessment aims to:

  • Identify potential ignition sources (machinery, electrical installations, storage of flammable products, etc.)
  • Analyze the consequences of a fire in the various areas (workshops, offices, storage areas…)
  • Evaluate the existing prevention and protection measures (alarms, extinguishers, sprinklers, staff training…)
  • Implement or improve evacuation and emergency management procedures

Components of fire risk

The risk assessment takes into account:

  • Possible causes of a fire outbreak:

    • Electrical faults or overheating
    • Thermal equipment or friction machinery
    • Storage of flammable substances (solvents, paper, plastics…)
    • Human error (negligence, handling of open flames…)
  • Aggravating factors:

    • No automatic detection or extinguishing system
    • Difficult evacuation
    • Insufficient maintenance of installations
    • Staff not trained in first-response actions
  • Prevention and protection measures:

    • Alert systems (smoke detectors, fire alarms…)
    • Firefighting equipment (extinguishers, RIA (hose reels), sprinkler systems…)
    • Fire safety organization (instructions, evacuation drills, safety register…)
    • Compliance with standards (Code du Travail (French Labor Code), ERP/IGH (buildings open to the public / high-rise buildings), ICPE (regulated industrial facilities)…)

Potential impacts

A fire can cause:

  • Injuries or even deaths among employees or visitors
  • Significant property damage (buildings, machinery, inventory…)
  • Business interruption losses (halt in operations, loss of customers…)
  • Legal or criminal penalties for the employer in case of failures to comply

Regulatory obligations

Assessing fire risk is a legal obligation under the Document Unique d'Évaluation des Risques Professionnels (DUERP, the French single document for occupational risk assessment).

The company must also:

  • Comply with the fire safety rules applicable to its activity (ERP, IGH, ICPE…)
  • Implement appropriate prevention measures
  • Train staff in evacuation procedures and first-response actions

Related risks

Fire risk is often linked to other risk categories that should be assessed together:

  • Machinery risk: electrical and mechanical equipment is a frequent cause of fire outbreaks
  • Business interruption: a fire usually causes a prolonged halt in operations
  • Civil liability: the company may be held liable for damage caused to third parties (neighbors, customers present on the premises)
  • Environmental risk: smoke and firefighting water can pollute the environment

How Hazadio assesses this risk

Hazadio analyzes fire risk using a structured methodology covering several areas:

  • Ignition sources: presence of flammable products, condition of electrical installations, thermal processes
  • Detection and alert systems: smoke detectors, alarms, detection control panel
  • Firefighting equipment: extinguishers, RIA (Robinets d'Incendie Armés, hose reels), sprinklers, fire blankets
  • Safety organization: staff training, evacuation drills, safety instructions
  • Regulatory compliance: compliance with the Code du Travail (French Labor Code), ERP/IGH standards where applicable, periodic inspections

The final score (from A to F) reflects the company's overall vulnerability to fire risk.

FAQ – Fire risk in business

Is a fire risk assessment mandatory?

Yes. Article R4227-1 of the Code du Travail (French Labor Code) requires employers to assess fire and explosion risks. This assessment must be included in the Document Unique d'Évaluation des Risques Professionnels (DUERP, the French single document for occupational risk assessment), which must be updated annually for companies with 11 or more employees.

What fire safety equipment is mandatory?

Under Articles R4227-28 et seq. of the Code du Travail, a company must have at least a sufficient number of fire extinguishers (1 unit per 200 m² (about 2,150 sq ft), with a minimum of one per floor), an audible alarm system, and the means to evacuate the premises quickly.

How often must fire extinguishers be inspected?

Fire extinguishers must be inspected annually by a qualified technician (Article R4227-39 of the Code du Travail). A ten-year overhaul with pressure retesting is also mandatory for permanently pressurized extinguishers.

Who must be trained in fire safety?

The employer must train all staff in evacuation instructions and first-response actions. First-response team members (EPI) and second-response team members (ESI) may be designated depending on the size and risks of the facility.

What insurance covers fire risk?

Commercial multi-peril insurance generally covers direct damage caused by a fire (buildings, equipment, inventory). Additional business interruption coverage is recommended to cover the financial consequences of a halt in operations.

Do premises in co-owned buildings have to comply?

Yes. A tenant company remains responsible for fire safety in the premises it occupies. It should review the lease clauses on insurance and compliance obligations.

What is an ERP and what specific obligations apply?

An Établissement Recevant du Public (ERP, an establishment open to the public) is subject to stricter rules set out in the Code de la Construction et de l'Habitation (French Construction and Housing Code). These establishments are classified by type (according to activity) and by category (according to capacity), with increasing obligations.

How can I reduce my fire insurance premium?

Installing prevention measures (sprinklers, automatic detection, fire doors) can help you negotiate premium reductions with your insurer. A formal risk audit also demonstrates proactive risk management, which insurers value.

Useful sources

  • INRS – Fire and explosion (INRS: French national research and safety institute for occupational health)
  • INRS – Sheet ED 990: Fire safety instructions
  • Ministry of Labor – Occupational risks
  • Code du Travail – Articles R4227-1 to R4227-57
  • Service-Public.fr – Fire safety in business
  • French Insurance Federation (FFA) – Fire insurance

Go further

  • SME insurance: check your coverage against this risk
  • For brokers: run your risk audits with Hazadio
v1.0.22

The risk assessment app for businesses

Identify weak points, put the right actions in place, and check that your insurance coverage is consistent.

Useful links

  • Pricing
  • Insurance brokers
  • SME insurance
  • About us

Legal

  • Privacy policy
  • Terms of use

Support & Help

  • Contact

Developed & Hosted in France

Developed byKevalco|All rights reserved